Measurements of mobile phone radiation

Measurements of mobile phone radiation

The Radiation and Nuclear Safety Authority (STUK) conducts market surveillance testing of mobile phones and other devices exposing the general public to radiofrequency radiation. Market surveillance tests are carried out on devices found on the market to check that the exposure caused by the devices does not exceed safe limits.

The manufacturer, importer or, ultimately, the distributor, is responsible for the safety of the sold product. The manufacturer must carry out conformity assessment before placing the product on the market and is held accountable for ensuring that the product complies with relevant requirements.

Specific Absorption Rate (SAR) describes the rate at which radiofrequency energy is absorbed per unit mass by a human body. In compliance assessment of mobile phones and other devices emitting radiofrequency radiation, SAR is used as a measure of the exposure caused by the device. The local SAR limit values are 2 W/kg for the head and trunk and 4 W/kg for limbs as set in the Decree 1045/2018 of the Ministry of Social Affairs and Health. The limit values include a considerable safety margin to the exposure level known to produce adverse health effect in humans.

Mobile phone manufacturers are required to measure the SAR of all models and to ensure that the limit values are not exceeded. The SAR values for new mobile phones are available on the manufacturer's website or in the user manual of the device.

STUK has carried out market surveillance testing on mobile phones since 2003 and on other devices since 2013. Measured SAR values for the tested devices are listed in the table below. The SAR measurement for devices used next to the ear is performed in accordance to the standard EN/IEC 62209-1. Devices intended for use in proximity of the human body are tested according to EN/IEC 62209-2.

During the SAR measurement, the device under test is set to transmit at full power and the measurement is performed in different operating positions. Setting the device to transmit at full power produces a worst-case scenario considering the exposure of the user to the radiofrequency energy emitted by the device. Under actual operating conditions mobile devices rarely transmit at full power. Instead, the devices adjust the transmit power based on the signal reception.

Mobile phones tested by STUK

Model of phone

SAR measured by STUK (W/kg)

SAR reported by manufacturer (W/kg)

Apple    
iPhone 4 1,07 0,93
iPhone 4S 0,712 0,988
Doro    
Doro PhoneEasy 345 0,52 0,692
HTC    
HTC Desire 0,73 0,752
HTC 7 Mozart 0,569 0,538
HTC 8S 0,518 0,721
Huawei    
U8850-1 0,59 0,761
Insmat    
BBM-820 0,44 0,198
LG     
LG C1100 1,00 1,12
LG KF600 0,44 0,471
LG KG110 1,12 0,728
LG KG275 0,96 0,956
LG KU250 1,23 1,24
LG L3100 1,23 0,30
 LG Optimus L7 0,709 0,76
Motorola    
Motorola C139 0,87 0,97
Motorola C200 0,80 0,78

Motorola C350

0,54

0,90

Motorola C550 0,79 0,71
Motorola C650 0,56 0,87
Motorola DEFY+ 0,804 1,09
Motorola F3 0,54 0,72
Motorola L6 1,13 1,33
Motorola T191 0,96 1,01

Motorola V150

0,56

0,67

Motorola V180

0,77 0,87
Motorola W180 0,61 0,51
Nokia    
 Nokia 113  1,18  1,46
Nokia 1100 0,68 0,67
Nokia 1112 0,65 0,78
Nokia 1600 0,62 0,82

Nokia 2100

0,55

0,55

Nokia 2330 Classic 0,88 0,98
Nokia 2600 0,53 0,80
Nokia 2610 0,58 0,56
Nokia 2630 0,65 0,70
Nokia 2650 0,48 0,54
Nokia 2690 0,48 0,66
Nokia 2720 0,68 0,96
Nokia 2760 0,82 0,97
Nokia 303 Asha 0,60 0,79

Nokia 3100

0,63

0,76

Nokia 3200 0,55 0,56
Nokia 3220 0,59 0,78

Nokia 3310

0,91

0,96

Nokia 3510

0,58

0,66

Nokia 3720 Classic 0,51 0,48
Nokia 5100 0,47 0,48
Nokia 5140 0,86 0,77
Nokia 5030 XpressMusic 0,94 1,06
Nokia 5230 XpressMusic 0,54 1,10
Nokia 6021 0,37 0,72
Nokia 6030 0,62 0,70
Nokia 6060 0,65 0,77
Nokia 6085 0,71 1,15

Nokia 6100

0,61

0,60

Nokia 6103 0,48 0,75
Nokia 6151 0,84 1,02
Nokia 6220 0,65 0,66
Nokia 6270 0,28 0,74
Nokia 6600i 0,33 0,35

Nokia 6610

0,97

0,63

Nokia 6630 0,69 0,83
Nokia 6700 Classic 0,29 0,41
Nokia 6810 0,87 0,82
Nokia 6822 0,71 0,67
Nokia 7230 0,62 0,97
Nokia 9500 Communicator 0,27 0,49
 Nokia Asha 303  0,60  0,79
Nokia C5 0,66 1,34
Nokia E51 0,97 1,47
Nokia E52 0,81 1,05
Nokia E65 0,53 0,87
Nokia E7 0,29 0,56
Nokia E71 0,53 1,33
Nokia E72 0,73 1,31
 Nokia Lumia 710  0,993  1,3
 Nokia Lumia 820  0,537  0,79
Nokia N70 1,01 0,95
Nokia N73 0,85 1,12
Nokia N97 Mini 0,50 0,67
Nokia N-Gage QD 0,48 0,57
 Nokia Lumia 920  0,697  0,68
Nu:fone    
Nu:fone Classic 0,86 -
Nu:fone Two 0,69 -
Samsung    
Samsung C3050 0,48 0,709
Samsung E1080 0,70 0,645
Samsung Galaxy Ace 0,70 0,84
Samsung GT-SC5230 0,70 0,531
Samsung SGH-A800 0,88 0,96
Samsung SGH-B100 0,77 0,91

Samsung SGH-C100

0,74

0,60

Samsung SGH-E330 1,17 0,90
Samsung SGH-L760 0,78 0,554
Samsung SGH-X100 0,54 0,76
Samsung SGH-X200 0,87 0,74
Samsung SGH-X300 0,39 0,58

Samsung SGH-X450

1,13 0,98

Samsung SGH-X460

0,79

0,846

Samsung SGH-X510

0,77 0,781
Samsung SGH-X680 0,59 0,801

Samsung SGH-X820

1,15 0,639

Samsung SGH-Z540

0,38 0,54
Siemens    

Siemens A55

0,45

0,56

Siemens A60 0,75 0,67
Siemens A65 0,28 0,49
Siemens A70 0,35 0,52

Siemens CF62

0,75 0,75

Siemens M55

0,80 0,64

Siemens MC60

0,60

0,67

Siemens ME45

1,12

0,98

SonyEricsson    
SonyEricsson F305 0,65 0,67
SonyEricsson J230i 0,70 0,98
SonyEricsson J300i 1,31 1,02

SonyEricsson K500i

0,53 0,53
SonyEricsson T230 0,50 0,74

SonyEricsson T310

0,53

0,61

SonyEricsson T630

0,85 0,88
SonyEricsson W100i 0,99 1,03
SonyEricsson W200i 0,72 0,81
SonyEricsson W300i 1,03 1,20
SonyEricsson W350i 1,41 1,46
SonyEricsson Z200 0,77 0,94
SonyEricsson Z300 0,90 0,75
SonyEricsson Z310i 0,43 0,7
 Sony Experia ST21i  0,957  1,62
Teddyfone 0,65 0,168
Telme    
Telme C115 0,91 0,873
 ViewSonic    
 ViewSonic V350  0,735  0,761
 Wiko    
 Wiko Cinc Five  0,42  0,639
ZTE    
ZTE Blade 0,94 1,35
Average 0,71 0,80
Maximum 1,41 1,62
Minimum 0,27 0,17